NHKMC1 Fire-Resistant Busway With 4P Or 5P And Rated Current 250A~6300A

The refractory busway is suitable for three-phase four-wire and three-phase five-wire supply and distribution systems with AC 50~60Hz, voltage 660V and below, rated current 250~3150A with high fire protection requirements. The product is made of insulating material with high temperature resistance above 500℃, while the heat insulation layer is made of heat insulation and temperature resistant material above 1000℃, and the shell is made of steel. The fire-resistant busway has passed the 950°C, 90-minute to 3-hour high-temperature fire test, as well as the full-load current-carrying test and the waterproof test, and the full set of standard tests for busways, so the selection of this busway can ensure the current-carrying capacity and the stability of power supply for fire-fighting equipment. This series of products can maintain power supply for a certain period of time in case of fire to ensure enough time to start fire-fighting equipment, smoke exhaust and ventilation, and evacuate people.

Request a Quote

PRODUCTS DETAILS

product detail

Product Parameters


Executive standard

IEC61439-6,GB7251.1,HB7251.6

System

Three-phase three-wire, three-phase four-wire, three-phase five-wire, three-phase five-wire (shell as PE)

Rated frequency f (Hz)

50/60

Rated insulation voltage Ui (V)

1000

Rated working voltage Ue (V)

380-690

current (A)

250A~6300


Product Technical Parameters


  1. NHCCX series busways are in compliance with IEC60439-1~2, GB7251.1-2, JISC8364, GB9978 standards for each performance.
  2. The busway can withstand 2500V frequency withstand voltage for 1min without breakdown and flashover.
  3. The busway is able to withstand strong electric and thermal stresses due to the use of high-strength ceramic as the phase separation material. According to the data in Table (2), the busways passed the dynamic and thermal stability test and showed undetectable ^ deformation after the test.


Rated working current(A)

250

400

630

800

1000

1250

1600

2000

2500

3150

Short-time withstand current(A)

10

15

20

30

30

40

40

50

60

75

Peak withstand current(A)

17

30

40

63

63

84

84

105

132

165


The temperature rise of the conductive parts of the busway trough does not exceed the values listed

in the following table when the rated current is passed for a long time

conductive part

Maximum allowable temperature rise(K)

connection terminals

60

Housing

30




Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return