6300A QBJGM Insulated Pipe Medium Voltage Busway

Product Details:

Place of Origin: CHINA
Certification: KEMA,ASTA,CE,GOST-R,CEDIT,TUV
Model Number: Q(B)JGM

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard package
Delivery Time: 20 working days after confirmation of all technical data and advance payment
Supply Ability: 300 Pieces per Month
Request a Quote

PRODUCTS DETAILS

6300A QBJGM Insulated Pipe Medium Voltage Busway

Description

Conductor Type: Cu Pipe / Al Pipe Rated Current: 630A--6300A
Frequency: 50Hz/60Hz Rated Voltage: 3.6-40.5KV
IP: IP65 Product Series: Semic Insulated / Insulated
Design Criteria: DL 1658 AND GB/T 8349 Product Type: Insulate Pipe Busduct
High Light: QBJGM Medium Voltage Busway, QBJGM Insulate pipe busduct, 6300A Medium Voltage Busway

Q ( B ) JGM insulated pipe busway , Insulate pipe busduct

 

To prevent accidental damage to internal shielding and primary insulation during manufacturing.
12 related patents designed.Prevent the introduction of external impurities between the main insulation layer and the inner shield, as well as the outer shield.
The internal and external shielding is closely combined with the main insulation layer, which improves the performance of partial discharge resistance and in the fight aganist wear.
The insulation material is made of high quality ethylene propylene diene diene rubber (EPDM), which not only has excellent electrical insulation performance and corona resistance, but also has aging resistance and corrosion resistance.
EPDM (ethylene propylene diene ternary rubber) adding with a variety of compounding agents, after being thoroughly mixed, extruded on a tubular conductor, and then heated and vulcanized.

Standards IEC364-5-54/GB/T8349-2000/JB/T9639-1999
Ambient  
Relative humidity   Daily averages ≤ 95%. Monthly average ≤ 90%
IP   IP40, IP54
Rated voltage kV 3.15 6.3 10.5 35
Max operating voltage kV 3.6 7.2 12 40.5
Insulation level kV 25/40 32/60 42/75 100/185
Rated frequency Hz 50(60)
Rated operating current   Dimension (W×H)(mm×mm)
1000-3000 A I 750×400 II 850×350 I 900×560 II 1060×460 I 900×560 II 1060×460 I 1500×920 II 1800×880
3500 A I 750×440 II 850×480 I 900×560 II 1060×460 I 900×560 II 1060×460  
4000 A I 750×440 II 850×480 I 900×560 II 1060×460 I 900×560 II 1060×460  
4500 A I 750×440 I 1000×560 I 1000×560  
5000 A I 1350×500 I 1500×600 I 1500×600  
6300-6800 A I 1350×500 I 1500×600 I 1500×600  

Q(B)JGM Insulation pipe busway is with tubular conductor. The inside diameter air channel can form hot air convection naturally with good dissipation (the pressure difference between indoor and outdoor can form hot air convection naturally).

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return